CERTUSS COMPONENTS

CERTUSS steam generators − The right choice for every application

Selected components from our own production and from renowned manufacturers are used during manufacturing. The provision together with complete accessories as a ready to operate, ready for connection unit (CVE) is a particular advantage of the CERTUSS offer. It saves time consuming and costly pre installation and offers factory tested safety and reliability. A wide range of additional equipment such as the Thermotimat control unit for fully automatic operation of our plants without personnel offer a compact high capacity system and a considerably reduced power requirement.

The CERTOMAT system of the SC series installed as standard represents the operating states of the steam generator, displays them in plain text and stores messages for detailed evaluations.

The touch screen of the TC series guides the operator graphically through all the application steps and when required provides access to system specific supplementary functions through to reminders for maintenance dates or further preventative measures for maintaining the operational reliability.

All the signals can be integrated in a process control system provided by the customer (GLT).

Inclusion of the steam generator control system in a company network is possible. The data transfer can be effected via Ethernet Switch directly or via interfaces, such as for example PROFIBUS, via DSL or GSM.

Find the suitable CERTUSS steam generator here
Top quality all the way ...
CERTUSS accessories are designed to meet individual requirements and correspond technically with the CERTUSS steam generators.

steam generator components certuss hrsfunke

Economiser CERTUSS

  • Flue gas heat exchanger for CERTUSS steam generators for the Junior 500-600 SC and the Universal 500-1800 TC series.
  • Uses exhaust gas heat to increase the temperature of the boiler feed water.
  • Reduced burner output under full steam generation.
  • Fuel reduction by up to 5 %.
  • Reduced emissions.
  • Internal energy recycling without external heat consumer.
  • Short amortization period.


CERTECON Economiser

  • Flue gas heat exchangers for CERTUSS steam generators Type Junior SC 80 - 400.
  • Uses exhaust gas heat to increase the temperature of the boiler feed water.
  • Reduced burner output under full steam generation.
  • Fuel reduction by up to 5 %.
  • Reduced emissions.
  • Internal energy recycling without external heat consumer.
  • Short amortization period.


Desalination heat exchanger

  • Energy recycling from the desalination condensate to heat feed water.
  • Reduction of the amount of cooling water at steam systems with wastewater cooling.


Feed water tank

  • With direct or indirect heating.
  • With direct or indirect insulation.
  • Control condensate elevating system optional.


Water softening equipment

  • Water preparation required: Semi or fully automatic, quantity or time dependent.
Measuring equipment

  • Supplement for water softening equipment.
  • For oxygen binding and corrosion protection.


PARCOVAP®

  • Condensate heat recovery for energy saving of 13%.


CVE supply unit

  • Ready for use installation of all components for supplying the steam generator.
  • Eliminates complex complex on site installations.
  • Offers factory tested functional reliability.